Zynq UltraScale+ MPSoC Power Advantage Tool 2019.1 ZCU111


Zynq UltraScale+ MPSoC Power Advantage Tool 2019.1 ZCU111

Now that you have installed and run the Pre-Built Power Advantage Tool, let’s take a moment to see what else you can do with it. The Power Advantage Tool Control Console can be used with designs, to monitor power during the design process. In addition, the Power Advantage Tool can be used as a demonstration of the power savings with various designs.\

Table of Contents

Table of Contents

Document History

DateVersionAuthorDescription of Revisions
Apr 3, 2019
jerrywoCreated


1 Power Advantage Tool


Known 2019.1 Issues:
(1) The MSP430 source builds the compatible MSP430 version, but may not support all MSP430 TI Code Composer Studio debug features.

Note: The Power Advantage Tool now takes control of the APU serial port if available. To give user control of the APU terminal, close the Power Advantage Tool, then launch the following script to open terminals, then open the Power Advantage Tool again. The Power Advantage Tool will complain that "No APU UART available", but just close that message.


1.1 Launching the Power Advantage Tool Control Console

Warning: If you have connected Micro USB (UART) (J83) to PC for the first time, or switched boards, you may need to wait a few minutes for the PC to recognize the new hardware. Then you can open the Power Advantage Tool.

Launch the Power Advantage Tool Shortcut at C:\ZynqUS_Demos\2019.1_Demos\ZynqusPowerTool.exe ZCU111 Shortcut.
In a few seconds, you should see a Power Advantage Tool Control Console window with a Power Report. The Power numbers should update every few seconds.
If it is not displayed properly, refer to “Common Setup Issues”, and debug until the “Power Advantage Tool is alive” before returning here to continue.

1.2 Getting to Know the Power Advantage Tool Control Console


After successfully launching the Power Advantage Tool, you should see the following Power Advantage Tool Control Console window (may take a few seconds):


Figure 1. Power Advantage Tool Control Console
This interface is important to most of the demonstrations, so it would be good to familiarize yourself with it. Take a moment to identify the following:
  • Zoom Display (transparent button [ ]) (A) resizes to fill a 1920x1080 display.
  • Close (transparent button [X]) (B)
  • Minimize (C)
  • Select (D) Selects the display mode (Rails, Plot, About contains the version number)
  • Preset (E) Not supported in this version.
  • Block Diagram of Zynq (F) shows the current device state.
  • Power Totals for various domains (G) (Note: There can be a few seconds delay for measurement and update.)

Here is a Table of the Rails for ZCU111:
  • VCC1V2 – DDR Termination
  • MGT1V2 – GTH Termination Power
  • MGT1V8 – GTH Power
  • VCCPSINT – PS Core Rail (Combined FPD and LPD)
  • VCC1V8 – Auxiliary Circuits
  • VCCINT – PL Core Rail
  • VADJ_FMC – Main FMC Rail
  • MGTAVCC – Receiver and Transmitter Internal
  • VCCINT_AMS – ADC and DAC Digital Logic
  • DAC_AVTT – DAC Termination
  • DAC_AVCCAUX – Analog for the custom DAC block
  • ADC_AVCC – Digital for the custom ADC block

  • ADC_AVCCAUX – Analog for the custom ADC block

  • DAC_AVCC – Digital for the custom DAC block

...