Zynq UltraScale+ MPSoC Power Advantage Tool 2017.1 ZCU106
Table of Contents
Now that you have installed and run the Pre-Built Power Advantage Tool, let’s take a moment to see what else you can do with it. The Power Advantage Tool Control Console can be used with designs, to monitor power during the design process. In addition, the Power Advantage Tool can be used as a demonstration of the power savings with various designs.
Document History
Date | Version | Author | Description of Revisions |
Aug 22, 2017 | jerrywo | Created | |
Dec 20, 2017 | jerrywo | Updated Power Advantage Tool |
1 Power Advantage Tool
Known 2017.1 Issues:
(1) The MSP430 source builds the compatible MSP430 version, but may not support all MSP430 TI Code Composer Studio debug features.
(2) For this release, SD cards must not be class (10) for reliable boot (e.g. class (4) is fine).
Note: This version of Power Advantage Tool Control Console no longer needs to be launched after Linux boot. It no longer uses the Power Sensor calibrations, so Linux can freely overwrite the Power Sensor calibrations. There is a small improvement to the measurement accuracy as well.
Note: The Power Advantage Tool now takes control of the APU serial port if available. To give user control of the APU terminal, close the Power Advantage Tool, then launch the following script to open terminals, then open the Power Advantage Tool again. The Power Advantage Tool will complain that "No APU UART available", but just close that message.
1.1 Launching the Power Advantage Tool Control Console
Warning: If you have connected Micro USB (UART) (J83) to PC for the first time, or switched boards, you may need to wait a few minutes for the PC to recognize the new hardware. Then you can open the Power Advantage Tool.Launch the Power Advantage Tool Shortcut at C:\ZynqUS_Demos\ZynqusPowerTool.exe Shortcut.
In a few seconds, you should see a Power Advantage Tool Control Console window with a Power Report. The Power numbers should update every few seconds.
If it is not displayed properly, refer to “Common Setup Issues”, and debug until the “Power Advantage Tool is alive” before returning here to continue.
1.2 Getting to Know the Power Advantage Tool Control Console
After successfully launching the Power Advantage Tool, you should see the following Power Advantage Tool Control Console window (may take a few seconds):
Figure 1. Power Advantage Tool Control Console
This interface is important to most of the demonstrations, so it would be good to familiarize yourself with it. Take a moment to identify the following:
- Zoom Display (transparent button [ ]) (A) resizes to fill a 1920x1080 display.
- Close (transparent button [X]) (B)
- Minimize (C)
- Select (D) Selects the display mode (Rails, Plot, About contains the version number)
- Preset (E) Places the ZCU106 into a selected state.
- Block Diagram of Zynq (F) shows the current device state.
- Power Totals for various domains (G) (Note: There can be a few seconds delay for measurement and update.)
Note: The Temperature is not supported in this demo version.
Here is a Table of the Rails for ZCU106:
- VCCPSINTFP – Core Full Power Domain
- MGTRAVCC – GTX Power
- MGTRAVTT – GTX Termination Power
- VCCO_PSDDR_504 – PS DDR Controller IO
- VCCPSDDRPLL – PS DDR PLL Power
- VCCPSINTLP – Core Low Power Domain
- VCCPSAUX – Aux and GPIO
- VCCPSPLL – PS PLL Power
- VCCOPS – PS IO Banks MIO0/1/2
- VCCOPS3 – Dedicated PS IO
- VCCINT – PL Operating
- VCCBRAM – Block RAM
- VCCAUX – Auxiliary Circuits
- VCC1V2 – DDR Termination
- VCC3V3 – Main PMBUS Utility Rails
- MGTAVCC – Receiver and Transmitter Internal
- MGTAVTT – Transmit Driver
It is a power advantage to be able to turn off unused circuitry. The more power islands and domains you have, the more flexibility you have to save power.
Islands are power switched internally to the Zynq UltraScale+ MPSoC, whereas Domains are powered externally to the Zynq device. When Domain or island switching can be done, this has the advantage of drawing no power by being able to completely turn off a portion of the silicon device.
Note: Switching off domains can clear the program memory until reboot.
Control can be over entire Domains or individual Islands.
1.3 Domain Control
Power Domains are broad sections of the Zynq UltraScale+ MPSoC and are the Full Power, Low Power, and Programmable Logic domains. The Power Advantage Tool requires no further setup to have access to the Power Domain Controls.
Figure 2. Power Domain Controls
With the Power Advantage Tool running, identify the following controls:
(A) Preset Button
(B) Low Power Domain Button
(C) FulI Power Domain Button
(D) Four A53 Processor Core Power Island Buttons (not supported in this demo)
(E) Programmable Logic Domain Button
1.4 Selecting Displays
Pressing the Select button gives a menu to select from various displays:
- Plot: Graphically displays the power for each of the three domains and total power.
Figure 4. Plot.
- Rails: This is the default display. Rails displays the voltage and power for each of the rails, as well as the chip temperature, and the total power. The power measurements are made external to the Zynq by TI INA226 chips.
Figure 5. Rails.
- Sysmon: Not supported in this demo.
- Legend: This page defines each of the Zynq rails.
Figure 6. Legend.
- About: This page contains the legal notice, as well as the software revisions for Qt and MSP430 code.
Figure 7. About.
Related Links
Home Previous Back Next© Copyright 2019 - 2022 Xilinx Inc. Privacy Policy