  • Verify hardware setup—see /wiki/spaces/XWUC/pages/1329201173User Guides for each board above. Board should be powered off at the start of tutorialthese instructions.

  • Set mode switch SW6 to 0010 (QSPI32). See available boot modes below.

  • Connect to power and the board’s 6-pin power supply (J52) and power on board. The kit will include an cable and power adapter for this purpose, as shown in the image below.

...

  • Power Check: The three rows of Power Good LEDs should glow green, indicating a good power system.

    • Note: Descriptions for each power and status LED are available in each board’s user guide provided at the top of this page. Refer to the table below to find the location of the descriptions for each board.

Board

Table #

Page

ZCU102

3-34

82

ZCU104

3-25

68

ZCU106

3-36

89

  • The DONE LED will glow green if/when the board is configured correctly.

  • The built-in self-test begins after board startup.

    • Pressing the POR_B switch or the SRST_B switch will turn off DONE LED, reconfigure board and restart BIST.

...

Refer to the table below for each board’s tests and PL LED test assignments. The tests will not necessarily run in LED # order/the order they are shown in this table.

Board

LED

Test

ZCU102

ZCU106

7

Clock

6

BRAM

5

PL-DDR4

4

PS-DDR4

3

Flash

2

I2C

1

DIP

0

PB

ZCU104

3 (Top left)

Clocking and Memory

2 (Top right)

EEPROM and I2C

1 (Bottom left)

DIP

0 (Bottom right)

PB

Board Callouts

More comprehensive component lists available in board user guides.

...

The following table can be used to determine mode switch configuration. Zynq Ultrascale+ MPSoC devices use switch SW6 for boot configuration. Refer to individual board callouts to locate switch.

Boot Mode

Mode Pins [3:0]

SW6 [4:1]

JTAG

0000

ON, ON, ON, ON

QSPI32

0010

ON, ON, OFF, ON

SD

1110

OFF, OFF, OFF, ON

Board System Controller GUI (BUI) Guide

...

  • The following operations can be run from the GPIO Commands tab to verify functionality.

    • Blink LEDs

    • Return state of DIP switch

    • Return PMU state

    • Return PS GPIO state

    • Return PL GPIO state

Related Links

...

...