This instruction page has been tested only on the Ultra96 v2 and Bus Pirate (official Seeed Studio) v3.6


Now that you have installed and run the Pre-Built Power Advantage Tool, let’s take a moment to see what else you can do with it. The Power Advantage Tool Control Console can be used with designs, to monitor power during the design process. In addition, the Power Advantage Tool can be used as a demonstration of the power savings with various designs.

Table of Contents

Table of Contents
excludeTable of Contents

Document History

DateVersionAuthorDescription of Revisions
Sep 21, 2020
jerrywoCreated

Power Advantage Tool Hardware

Power Advantage Tool Parts 


If you do not already have an Ultra96 v2 that is set up for Power Advantage Tool
NoteKnown 2020.2 Issues:
(1) The MSP430 source builds the compatible MSP430 version, but may not support all MSP430 TI Code Composer Studio debug features
monitoring, you can make one:
Ultra96 v2
Bus Pirate (official Seeed Studio v3.6) can be ordered at https://www.seeedstudio.com/Bus-Pirate-v3-6-universal-serial-interface-p-609.html
5" or longer ribbon cable to female pin sockets
Micro USB cable
Velcro Dots
Image Added

Power Advantage Tool Fabrication


Image Added
  • Ribbon Cable: Strip 5” length to female pin sockets, solder darkest wire to Ultra96 GND, brightest wire to SCL (CLK), and mid wire to SDA (MOSI)
  • Bus Pirate (Seeed Studio) v3.6: Attach female ribbon cable sockets to Bus Pirate connector GND pin 10,  CLK (SCL) pin 4, and MOSI (SDA) pin 3
  • Velcro dots: Mount Bus Pirate to back side of Ultra96
  • Mini USB: Attach to Bus Pirate to PC. This powers the Bus Pirate via USB power.

Power Advantage Tool


Launching the Power Advantage Tool Control Console

Warning

If you have connected Bus Pirate Mini USB (UART) to PC for the first time, or switched boards, you may need to wait a few minutes for the PC to recognize the new hardware. Then you can open the Power Advantage Tool.


Launch the Power Advantage Tool Shortcut at C:\ZynqUS_Demos\2020.2_Demos\ZynqusPowerTool.exe Ultra96 Shortcut. 
In a few seconds, you should see a Power Advantage Tool Control Console window with a Power Report. The Power numbers should update every few seconds.
If it is not displayed properly, refer to “Common Setup Issues”, and debug until the “Power Advantage Tool is alive” before returning here to continue.

Info

The Power Advantage Tool now takes control of the APU serial port if available. To give user control of the APU terminal, close the Power Advantage Tool, then launch the following script to open terminals, then open the Power Advantage Tool again. The Power Advantage Tool will complain that "No APU UART available", but just close that message.




Launching the Power Advantage Tool Control Console

Warning

If you have connected Micro USB (UART) (J83) to PC for the first time, or switched boards, you may need to wait a few minutes for the PC to recognize the new hardware. Then you can open the Power Advantage Tool.


Launch the Power Advantage Tool Shortcut at C:\ZynqUS_Demos\2020.2_Demos\ZynqusPowerTool.exe ZCU111 Ultra96 Shortcut. (ZCU208 and ZCU216 use the ZCU216 Shortcut instead)   
In a few seconds, you should see a Power Advantage Tool Control Console window with a Power Report. The Power numbers should update every few seconds.
If it is not displayed properly, refer to “Common Setup Issues”, and debug until the “Power Advantage Tool is alive” before returning here to continue.

Getting to Know the Power Advantage Tool Control Console


After successfully launching the Power Advantage Tool, you should see the following Power Advantage Tool Control Console window (may take a few seconds):


Figure 1. Power Advantage Tool Control Console

This interface is important to most of the demonstrations, so it would be good to familiarize yourself with it. Take a moment to identify the following:
  • Zoom Display (transparent button [ ]) (A) resizes to fill a 1920x1080 display.
  • Close (transparent button [X]) (B)
  • Minimize (C)
  • Select (D) Selects the display mode (Rails, Plot, About contains the version number)
  • Preset (E) Not supported in this version.
  • Block Diagram of Zynq (F) shows the current device state.
  • Power Totals for various domains (G) (Note: There can be a few seconds delay for measurement and update.)

Here is a Table of the Rails for ZCU111Ultra96:
DAC_AVTT voltage measured is one half of the actual due to the sense point being used. Power Advantage Tool doubles this measured value to display the correct value.
  • VCC1V2 – DDR Termination
  • MGT1V2 – GTH Termination Power
  • MGT1V8 – GTH Power
  • VCCPSINT – PS Core Rail (Combined FPD and LPD)
  • VCC1V8 VCCINT – PL Core Rail
  • VCCAUX – Auxiliary Circuits
  • VCCINT – PL Core Rail
  • VADJ_FMC – Main FMC Rail
  • MGTAVCC – Receiver and Transmitter Internal
  • VCCINT_AMS – ADC and DAC Digital Logic
  • DAC_AVTT – DAC Termination
  • DAC_AVCCAUX – Analog for the custom DAC block
  • ADC_AVCC – Digital for the custom ADC block
  • ADC_AVCCAUX – Analog for the custom ADC block
  • DAC_AVCC – Digital for the custom DAC block
Info
  • VCC3V3 – Main PMBUS Utility Rails
  • VCCINTFP – Core Full Power Domain
  • VCCO_HP – PS DDR Controller IO
  • VCCPSINTLP – Core Low Power Domain
  • VCCPSAUX – Aux and GPIO



It is a power advantage to be able to turn off unused circuitry. The more power islands and domains you have, the more flexibility you have to save power.

...